Published October 2003 | Version v1
Miscellaneous

The measurement of oxide layer thickness of the irradiated fuel rod

  • 1. KAERI, Taejon (Korea, Republic of)

Description

The oxide layer thickness of fuel rod irradiated for 2 cycles in the Kori-2 unit reactor was measured by using the measurement by the eddy current system. Using standard specimens, the oxide layer measurement apparatus was calibrated, and also the measurement method was established. The oxide layer thickness of the irradiated fuel rod gradually increased from a few of μm to 23μm as the maximum value at 3000mm from the bottom end of fuel rod. The oxide layer thicknesses examined by the measurement of the layer thickness are in good agreement with those examined by a metallographic examination. This suggest that the examination of oxide layer of irradiated fuel rod is reliable as the same as the metallographic examination

Part of:
Analysis of unsteady turbulent parallel triple-jet flow with temperature difference

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS autumn meeting
Imprint Pagination
[CD-ROM]
Journal Page Range
[6 p.]

Conference

Title
2003 spring meeting of the KNS
Dates
29-30 May 2003
Place
Gyeongju (Korea, Republic of)

Optional Information

Notes
6 refs, 5 figs, 1 tab