A sequential test procedure for materials accountancy is presented where a final decision at the end of a defined number of balance periods is made concerning the loss of material. It is shown how false-alarm probability at single steps influences the false-alarm probability for the total time period. (author)

Files

14800206.pdf

Files (456.0 kB)

Name Size Download all
md5:2670e5f4d3617908a60e999c253075cd
456.0 kB Preview Download

Additional details

Publishing Information

Publisher
IAEA.
Imprint Place
Vienna
ISBN
92-0-070183-3
Imprint Title
Nuclear safeguards technology 1982
Imprint Pagination
580 p.
Series
Proceedings series.
Journal Page Range
v. 2 p. 383-392.

Conference

Title
International symposium on recent advances in nuclear material safeguards.
Dates
8-12 Nov 1982.
Place
Vienna (Austria).

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
14800206
Subject category
S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ACCOUNTING; DETECTION; INSPECTION; INVENTORIES; MATERIAL BALANCE; NUCLEAR MATERIALS DIVERSION; NUCLEAR MATERIALS MANAGEMENT; PROBABILITY; SAFEGUARDS; STATISTICS
Descriptors DEC
MANAGEMENT; MATHEMATICS

Optional Information

Secondary number(s)
IAEA-SM--260/5.