Published 1983
| Version v1
Book
Open
Truncated sequential test procedure using the CUMUF statistic for a timely detection of diversion
Creators
- 1. Kernforschungszentrum Karlsruhe G.m.b.H. (Germany, F.R.). Inst. fuer Datenverarbeitung in der Technik
Description
A sequential test procedure for materials accountancy is presented where a final decision at the end of a defined number of balance periods is made concerning the loss of material. It is shown how false-alarm probability at single steps influences the false-alarm probability for the total time period. (author)
Files
14800206.pdf
Files
(456.0 kB)
| Name | Size | Download all |
|---|---|---|
|
md5:2670e5f4d3617908a60e999c253075cd
|
456.0 kB | Preview Download |
Additional details
Publishing Information
- Publisher
- IAEA.
- Imprint Place
- Vienna
- ISBN
- 92-0-070183-3
- Imprint Title
- Nuclear safeguards technology 1982
- Imprint Pagination
- 580 p.
- Series
- Proceedings series.
- Journal Page Range
- v. 2 p. 383-392.
Conference
- Title
- International symposium on recent advances in nuclear material safeguards.
- Dates
- 8-12 Nov 1982.
- Place
- Vienna (Austria).
INIS
- Country of Publication
- International Atomic Energy Agency (IAEA)
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 14800206
- Subject category
- S98: NUCLEAR DISARMAMENT, SAFEGUARDS AND PHYSICAL PROTECTION;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ACCOUNTING; DETECTION; INSPECTION; INVENTORIES; MATERIAL BALANCE; NUCLEAR MATERIALS DIVERSION; NUCLEAR MATERIALS MANAGEMENT; PROBABILITY; SAFEGUARDS; STATISTICS
- Descriptors DEC
- MANAGEMENT; MATHEMATICS
Optional Information
- Secondary number(s)
- IAEA-SM--260/5.