Compression force and radiation dose in the Norwegian Breast Cancer Screening Program

  • 1. Department of Life Sciences and Health, Faculty of Health Sciences, Oslo and Akershus University College of Applied Sciences, P.O. 4 St. Olavs Plass, 0130 Oslo (Norway)
  • 2. The Cancer Registry of Norway, P.O. 5313 Majorstuen, 0304 Oslo (Norway)

Description

Highlights: • Compression force and radiation dose for 17 951 screening mammograms were analyzed. • Large variations in mean applied compression force between the breast centers. • Limited associations between compression force and radiation dose. - Abstract: Purpose: Compression force is used in mammography to reduce breast thickness and by that decrease radiation dose and improve image quality. There are no evidence-based recommendations regarding the optimal compression force. We analyzed compression force and radiation dose between screening centers in the Norwegian Breast Cancer Screening Program (NBCSP), as a first step towards establishing evidence-based recommendations for compression force. Materials and methods: The study included information from 17 951 randomly selected screening examinations among women screened with equipment from four different venors at fourteen breast centers in the NBCSP, January-March 2014. We analyzed the applied compression force and radiation dose used on craniocaudal (CC) and mediolateral-oblique (MLO) view on left breast, by breast centers and vendors. Results: Mean compression force used in the screening program was 116N (CC: 108N, MLO: 125N). The maximum difference in mean compression force between the centers was 63N for CC and 57N for MLO. Mean radiation dose for each image was 1.09 mGy (CC: 1.04mGy, MLO: 1.14mGy), varying from 0.55 mGy to 1.31 mGy between the centers. Compression force alone had a negligible impact on radiation dose (r2 = 0.8%, p = < 0.001). Conclusion: We observed substantial variations in mean compression forces between the breast centers. Breast characteristics and differences in automated exposure control between vendors might explain the low association between compression force and radiation dose. Further knowledge about different automated exposure controls and the impact of compression force on dose and image quality is needed to establish individualised and evidence-based recommendations for compression force.

Availability note (English)

Available from http://dx.doi.org/10.1016/j.ejrad.2016.12.025

Additional details

Identifiers

DOI
10.1016/j.ejrad.2016.12.025;
PII
S0720-048X(16)30419-3;

Publishing Information

Journal Title
European Journal of Radiology
Journal Volume
88
Journal Page Range
p. 41-46
ISSN
0720-048X
CODEN
EJRADR

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
49011397
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; COMPRESSION; EQUIPMENT; IMAGES; MAMMARY GLANDS; NEOPLASMS; RADIATION DOSES; SCREENING
Descriptors DEC
BODY; DIAGNOSTIC TECHNIQUES; DISEASES; DOSES; GLANDS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY

Optional Information

Copyright
Copyright (c) 2016 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.