Published July 24, 2019
| Version v1
Journal article
Prevalence and clinical significance of discordant LI-RADS® observations on multiphase contrast-enhanced MRI in patients with cirrhosis
Creators
- 1. University of Texas Southwestern Medical Center. Advanced Imaging Research Center (United States)
- 2. University of Texas Southwestern Medical Center. Department of Radiology (United States)
- 3. University of Texas Southwestern Medical Center. Department of Internal Medicine (United States)
Description
Purpose
To determine the prevalence and clinical significance of discordant LI-RADS® (Liver Imaging Reporting and Data System) liver observations on multiphase contrast-enhanced (MCE) magnetic resonance imaging (MRI) in patients with cirrhosis.Methods
This cross-sectional study included 93 cirrhosis patients who underwent 1.5 or 3 T MCE MRI for evaluation of hepatocellular carcinoma (HCC). Two abdominal radiologists independently reviewed T1-, T2-, diffusion-weighted unenhanced images as well as MCE T1-weighted fat-suppressed images and reported liver observations using LI-RADS®. Concordance were recorded for detection (co-detected by both radiologists or not), size category (< 10; 10–19; ≥ 20 mm), and LI-RADS® category assignment as reportable (LR-3/4/5/M) and actionable (LR-4/5/M). The overall concordance (i.e., concordant in detection, size, and LR-category) was calculated with 95% confidence interval [CI], and separately for detection, size, and LR-category. Clinical significance of discordance was assessed as impact on follow-up imaging, referral for biopsy, liver transplant eligibility, or treatment modality.Results
Reportable and actionable observations were overall concordant between two radiologists only in 32.3% [24.6, 41.0] and 40.1% [29.5, 51.5] of cases, respectively. Poor overall concordance was related to detection concordance of 52.0% [44.3, 59.5] and 62.5% [52.3, 71.8], as well as LR-category concordance of 73.7% [61.6, 83.1] and 70.9% [57.3, 81.6], for reportable and actionable observations, respectively. Discordant LI-RADS® observations would have impacted clinical management in 30 subjects (43.5%), most (66.7%) of whom were due to discordant detection.Conclusion
Discordant MRI LI-RADS® observations are common in patients with cirrhosis and may have potential implications for patient management.Additional details
Identifiers
Publishing Information
- Journal Title
- Abdominal Radiology (Online)
- Journal Volume
- 45
- Journal Issue
- 1
- Journal Page Range
- p. 177-187
- ISSN
- 2366-0058
INIS
- Country of Publication
- United States
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 55057601
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ABDOMEN; BIOPSY; CONTRAST MEDIA; DETECTION; EVALUATION; HEPATOMAS; IMAGES; LIVER; MAGNETIC RESONANCE; NMR IMAGING; PATIENTS; RELAXATION TIME; SIZE; SPECIFICITY; WEIGHTING FUNCTIONS
- Descriptors DEC
- BODY; CARCINOMAS; DIAGNOSTIC TECHNIQUES; DIGESTIVE SYSTEM; DISEASES; FUNCTIONS; GLANDS; NEOPLASMS; ORGANS; RESONANCE
Optional Information
- Copyright
- Copyright (c) 2019 © Springer Science+Business Media, LLC, part of Springer Nature 2019