Published January 2007 | Version v1
Journal article

Profiling of selenium removal in hydrogen ambient zone-refined tellurium bar using RF-GDOES

  • 1. Ultrapure Materials Division Center for Materials for Electronics Technology (C-MET), IDA, Phase-II, HCL Post, Cherlapalli, Hyderabad-500 051 (India)

Description

Ultrapure tellurium (Te) metal has become an important metal in the strategic sector for fabricating high performance infrared devices for thermal imaging and night vision cameras. Zone refining (ZR) is a proven technique for purification of Te. Selenium (Se), present as an impurity in Te, is not easily removed by ZR under normal conditions as the segregation coefficient (K) is around 0.44-0.50. Hence, ZR was performed in a hydrogen atmosphere, during which Se gets converted to hydrogen selenide at the molten moving zones and carried away into the sodium hydroxide scrubbers. In this study a radio-frequency glow discharge optical emission spectrometer (RF-GDOES) was used for determining the concentration of Se along the 56 cm Te zone-refined bar. It was observed that the initial concentration of 1100 ppb Se was decreased to 30 ppb after 2 cycles

Additional details

Identifiers

DOI
10.1016/j.matchar.2006.03.013;
PII
S1044-5803(06)00094-5;

Publishing Information

Journal Title
Materials Characterization
Journal Volume
58
Journal Issue
1
Journal Page Range
p. 92-95
ISSN
1044-5803
CODEN
MACHEX

Optional Information