Performance characteristics of a planar positron camera with slot collimators
Description
The UNICON, in positron mode, consists of two large field-of-view scintillation cameras in coincidence, on a rotating gantry. With bare crystals the sensitivity to singles counts and chance coincidences from activity beyond the system field of view causes increased dead time and very low maximum detected coincidence rate. Use of a collimator for each detector with slots orthogonal to the axis of rotation reduces the sensitivity to outlying activity. A clinically realistic distribution of sources and absorbers produced a maximum coincidence rate of 300/sec with bare crystals. This was increased to 4000/sec using collimators with 1 cm-wide slots, 1 cm-thick septa, 7.5 cm deep. A graded filter of lead and copper between collimator and crystal face increased the maximum detected rate to 6000/sec. Detector electronics are relatively standard so that compatability is maintained with UNICON operation in single photon mode. Detector dead times, detected spectra, system sensitivity and resolution, and chance coincidence fractions are presented for bare detectors, collimated detectors, and collimated detectors with graded filters. The slot collimators provide a system geometry similar to ring detector PET units, and allow use of those reconstruction algorithms as well as true 3D algorithms
Additional details
Publishing Information
- Journal Title
- J. Nucl. Med.
- Journal Volume
- 25
- Journal Issue
- 5
- Series
- J. Nucl. Med.
- Journal Page Range
- 102
- ISSN
- 0022-3123
- CODEN
- JNMEA
Conference
- Title
- 31. annual meeting of the Society of Nuclear Medicine.
- Dates
- 5-8 Jun 1984.
- Place
- Los Angeles, CA (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 18037910
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- ALGORITHMS; COINCIDENCE METHODS; COLLIMATORS; CRYSTALS; OPTICAL FILTERS; PERFORMANCE TESTING; PHOTONS; POSITRON CAMERAS; POSITRON COMPUTED TOMOGRAPHY; RESOLUTION; ROTATION; SCINTILLATION COUNTERS; SENSITIVITY; SPECTRA
- Descriptors DEC
- BOSONS; CAMERAS; COMPUTERIZED TOMOGRAPHY; COUNTING TECHNIQUES; ELEMENTARY PARTICLES; EMISSION COMPUTED TOMOGRAPHY; FILTERS; GAMMA CAMERAS; MASSLESS PARTICLES; MEASURING INSTRUMENTS; RADIATION DETECTORS; TESTING; TOMOGRAPHY
Optional Information
- Secondary number(s)
- CONF-840619--.