Published May 2021 | Version v1
Journal article

Early detection of subclinical pathology in patients with stable kidney graft function by arterial spin labeling

  • 1. Department of Nephrology, Shanghai General Hospital, Shanghai Jiao Tong University School of Medicine, 200080, Shanghai (China)
  • 2. National Clinical Research Center of Kidney Diseases, Jinling Hospital, Medical School of Nanjing University, 305 Zhongshan East Road, Xuanwu District, 210002, Nanjing, Jiangsu Province (China)
  • 3. Department of MRI, The First People's Hospital of Yunnan Province, The Affiliated Hospital of Kunming University of Science and Technology, 650032, Kunming, Yunnan (China)
  • 4. Department of Medical Imaging, Jinling Hospital, Clinical School of Southern Medical University, 210002, Nanjing, Jiangsu Province (China)
  • 5. MR Research, GE Healthcare, Shanghai (China)
  • 6. Department of Medical Imaging, Jinling Hospital, Medical School of Nanjing University, 210002, Nanjing, Jiangsu Province (China)

Description

To evaluate the utility of arterial spin labeling (ASL) for the identification of kidney allografts with underlying pathologies, particularly those with stable graft function. A total of 75 patients, including 18 stable grafts with normal histology (normal group), 21 stable grafts with biopsy-proven pathology (subclinical pathology group), and 36 with unstable graft function (unstable graft group), were prospectively examined by ASL magnetic resonance imaging. Receiver operating characteristic curves were generated to calculate the area under the curve (AUC), sensitivity, and specificity. Patient demographics among the 3 groups were comparable. Compared with the normal group, kidney allograft cortical ASL values decreased in the subclinical pathology group and the unstable graft group (204.7 ± 44.9 ml/min/100 g vs 152.5 ± 38.9 ml/min/100 g vs 92.3 ± 37.4 ml/min/100 g, p < 0.001). The AUC, sensitivity, and specificity for discriminating allografts with pathologic changes from normal allografts were 0.92 (95% CI, 0.83-0.97), 71.9%, and 100% respectively by cortical ASL and 0.82 (95% CI, 0.72-0.90), 54.4%, and 100% respectively by serum creatinine. The cortical ASL identified allografts with subclinical pathology among patients with stable graft function with an AUC of 0.80 (95% CI, 0.64-0.91), sensitivity of 57.1%, and specificity of 88.9%. Combined use of proteinuria and cortical ASL could improve the sensitivity and specificity to 76.2% and 100% respectively for distinguishing the subclinical pathology group from the normal group. Cortical ASL is useful for the identification of allografts with underlying pathologies. More importantly, ASL showed promise as a non-invasive tool for the clinical translation of identifying kidney allografts with subclinical pathology.

Additional details

Identifiers

Publishing Information

Journal Title
European Radiology
Journal Volume
31
Journal Issue
5
Journal Page Range
p. 2687-2695
ISSN
0938-7994
CODEN
EURAE3