Published October 1985 | Version v1
Journal article

A low shunt impedance 53 MHz rf system for rf stacking in the fermilab antiproton accumulator

  • 1. Fermilab

Description

In the Fermilab antiproton Accumulator Ring, injected antiprotons are to be adiabatically captured and rf stacked at the edge of the stochastic cooling stack tail. Also large antiproton bunches which have been removed from the cooled core by low-frequency rf unstacking are to be pre-bunched at 52.813 MHz prior to bunch-to-bucket transfer to the main Ring at 8 GeV. A 100 kV 53 MHz rf system for accomplishing these two tasks is described. Because of the low momentum spread beam to be stored in the ring, a shunt impedance limitation must be imposed on all devices in the ring to prevent microwave instability. Also vacuum pressure in the range 10-10 T must be maintained. This report describes how a normally high Q rf structure has been modified to meet these requirements

Additional details

Publishing Information

Journal Title
IEEE Trans. Nucl. Sci.
Journal Volume
NS-32
Journal Issue
5
Series
IEEE Trans. Nucl. Sci.
Journal Page Range
2803-2805
ISSN
0018-9499
CODEN
IETNA

Conference

Title
Particle accelerator conference.
Dates
13-16 May 1985.
Place
Vancouver (Canada).

INIS

Optional Information

Secondary number(s)
CONF-850504--.