Published 2005 | Version v1
Miscellaneous

Bias Voltage Effects on the Removal of Co and Mo by SF6/O2 Plasma for Radioactive Waste Decontamination

  • 1. Joongang Inspection Co., Ltd., Seoul (Korea, Republic of)

Description

The equipments and components used in nuclear power plant such as piping and valves usually are contaminated by TRU elements and radioactive corrosion and fission products. In this experiment, the principle contaminants Co of corrosion product and Mo of fission product are examined by SF6/O2 plasma. To enhance the reaction rate, DC bias voltage is applied on the specimens. Experimental results demonstrate the applicability and effectiveness of plasma decontamination processing. Results show that the reaction rate of molybdenum is 10.21 um/min. at 290 .deg. C. In the case of cobalt, etching reaction hardly takes place at low temperatures. However, it begins to increase as temperature exceeds 350 .deg. C. The reaction rate is 2.56 um/min. at 420 .deg. C. Ion-assisted experiments are under conduction. To support these results OES, SEM, and AES analysis are followed

Part of:
Proceedings of the KNS autumn meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Taejon (Korea, Republic of)
Imprint Title
Proceedings of the KNS autumn meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[2 p.]

Conference

Title
2005 autumn meeting of the KNS
Dates
27-28 Oct 2005
Place
Busan (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
37072017
Subject category
S12: MANAGEMENT OF RADIOACTIVE WASTES, AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
CORROSION; ELECTRIC POTENTIAL; NUCLEAR POWER PLANTS; PLASMA; RADIOACTIVE WASTES; REMOVAL
Descriptors DEC
CHEMICAL REACTIONS; MATERIALS; NUCLEAR FACILITIES; POWER PLANTS; RADIOACTIVE MATERIALS; THERMAL POWER PLANTS; WASTES

Optional Information

Notes
8 refs, 5 figs