Published September 1, 2019 | Version v1
Journal article

ReconSocket: a low-latency raw data streaming interface for real-time MRI-guided radiotherapy

  • 1. Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht (Netherlands)

Description

With the recent advent of hybrid MRI-guided radiotherapy systems, continuous intra-fraction MR imaging for motion monitoring has become feasible. The ability to perform real-time custom image reconstructions is however often lacking. In this work we present a low-latency streaming solution, ReconSocket, which provides a real-time stream of k-space data from the magnetic resonance imaging (MRI) to custom reconstruction servers.

We determined the performance of the data streaming by measuring the streaming latency (i.e. non-zero time delay due to data transfer and processing) and jitter (i.e. deviations from periodicity) using an ultra-fast 1D MRI acquisition of a moving phantom. Simultaneously, its position was recorded with near-zero time delay. The feasibility of low-latency custom reconstructions was tested by measuring the imaging latency (i.e. time delay between physical change and appearance of that change on the image) for several non-Cartesian 2D and 3D acquisitions using an in-house implemented reconstruction server.

The measured streaming latency of the ReconSocket interface was ms. 98% of the incoming data packets arrived within a jitter range of 367 s. This shows that the ReconSocket interface can provide reliable real-time access to MRI data, acquired during the course of a MRI-guided radiotherapy fraction.

The total imaging latency was measured to be 221 ms (2D) and 3889 ms (3D) for exemplary acquisitions, using the custom image reconstruction server. These imaging latencies are approximately equal to half of the temporal footprint (T acq/2) of the respective 2D and 3D golden-angle radial sequences. For radial sequences, it was previously showed that T acq/2 is the expected contribution of only the data acquisition to the total imaging latency. Indeed, the contribution of the non-Cartesian reconstruction to the total imaging latency was minor (<10%): 21 ms for 2D, 300 ms for 3D, indicating that the acquisition, i.e. the physical encoding of the image itself is the major contributor to the total imaging latency. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1361-6560/ab3e99

Additional details

Identifiers

Publishing Information

Journal Title
Physics in Medicine and Biology
Journal Volume
64
Journal Issue
18
Journal Page Range
[9 p.]
ISSN
0031-9155
CODEN
PHMBA7

INIS

Country of Publication
United Kingdom
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
52004011
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
DATA ACQUISITION; IMAGE PROCESSING; INTERFACES; NMR IMAGING; RADIOTHERAPY; STREAMS; TIME DELAY
Descriptors DEC
DATA PROCESSING; DIAGNOSTIC TECHNIQUES; MEDICINE; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; RIVERS; SURFACE WATERS; THERAPY