Forecasting the radiation conditions in the box of deaerator and steam separator at the Bilibino NPP

Description

Data on the γ-radiation dose rate fields for the Bilibino NPP unprotected deaerator and steam separator equipment, calculated according to the KONTUR program and measured using the DRG3-02 dosemeter are presented. A possibility of computerized forecasting of sufficiently non-uniform dose rate fields with 20-40% error using the KONTUR program is demonstrated as a result of analysis conducted for radiation of 16N and corrosion product isotopes

Additional details

Additional titles

Original title (Russian)
Прогнозирование радиационной обстановки внутри бокса деаэратора и сепаратора Билибинской AEhS

Publishing Information

Imprint Title
Construction and building
Journal Issue
no. 2
Series
Voprosy atomnoj nauki i tekhniki.
Journal Page Range
p. 3-8.
Report number
INIS-SU--75

Optional Information

Notes
2 refs.; 3 tabs. Imprint:Proektirovanie i stroitel'stvo.;Nauchno-tekhnicheskij sbornik.