Published 1988 | Version v1
Miscellaneous

Preparation and dosimetric properties of GeS as a radiothermoluminescence dosimeter

Description

A detailed description of a method for preparing GeS in an amorphous form is presented. The radiothermoluminescence (RTL) dosimetric properties of GeS were optimized by varying the percentage abundance of the dopant (sulphur). The results characterizing the optimized prepared glass composition (GeS3) yielded a linear dose response versus RTL output to 10 KGY for samples exposed to gamma radiation. Further, samples of GeS3 irradiated by neutron fluences exhibit linear response (105 - 1010 n/cm2). Moreover, the fading behaviour was studied. It is found that after a room decay time of 4 weeks post samples irradiation, the fading behaviour stabilized and approached an order of 4-5% per month. The obtained GeS3 offered good reproducibility and high degree of stability which are desirable for dosimetric utilization in various fields of radiation applications

Additional details

Publishing Information

Publisher
Egyptian Society of Nuclear Sciences and Applications.
Imprint Place
Cairo (Egypt)
Imprint Title
Proceedings of the fourth Conference on Nuclear Sciences and Applications. Vol. 2
Imprint Pagination
426 p.
Journal Page Range
p. 623-630.
Report number
INIS-mf--12745

Conference

Title
4. Conference of Nuclear Sciences and Applications.
Dates
6-10 Mar 1988.
Place
Cairo (Egypt).

INIS