A study of densitometry comparison among three radiographic processing solutions

  • 1. Tehran University of Medical Sciences, School of Allied Medical Sciences, Department of Radiology Technology, Tehran(Iran, Islamic Republic of)
  • 2. Tehran University of Medical Sciences, School of Dentistry, Department of Oral Radiology, Tehran(Iran, Islamic Republic of)

Description

The radiographic image accuracy depends on the X-ray film information visibility. Good visibility is found by good contrast. Radiation exposure parameters (kVp, mAs) and film processing conditions have impact on contrast. In dentistry radiography machines, exposure time and processing procedure are set by radiographer. No optimized exposure time and processing conditions may lead to incorrect diagnosis and re-exposure of the patient. Therefore, we studied the performance of the three different available processing solutions with dental X-ray film. Materials and Methods: Dental intraoral E-speed films, size 2 (Kodak company, USA) were used in this study. These films were developed in a manual processor using three different brands of processing solution: 1) Taifsaz (Iran), 2) Darutasvir (Iran) and 3) Agfa (Germany) for temperatures of 25digC, 28digC and 30digC at the three different exposure times, 0.2 s, 0.25 s and 0.35 s. Performance was evaluated with respect to base plus fog, relative contrast and relative speed. Results: Darutasvir processing solution as the cheapest one showed higher base plus fog density at 25digC and 30digC than that of Taifsaz and Agfa solutions. Also, Darutasvir solution was found to have better relative contrast than that of the others, except for 30digC at 0.25 s. Relative speed was higher in Darutsavir solution than Agfa for 25digC at three exposure times used in this study, for 28digC at 0.2 s and for 30digC at 0.35 s. Taifsaz Processing solution was in the second order with respect to tested conditions. Conclusion: Comparison among available X-ray film processing solutions for different temperatures at different exposure times can help to maintain image quality while patient exposure and film cost are kept considerably low

Availability note (English)

Available from Atomic Energy Organization of Iran

Additional details

Publishing Information

Journal Title
Iranian Journal of Radiation Research (Print)
Journal Volume
4
Journal Issue
no.2
Journal Page Range
p. 81-86
ISSN
1728-4554