Published July 2015
| Version v1
Journal article
Application research on loose part monitoring system of nuclear power plant
Description
The different reasons of LPMS alarm in nuclear power plant have been analyzed. Based on this analysis, the analysis steps for Hainan nuclear power plant in case a LPMS alarm was proposed. The management measure for LPMS alarm analysis process of a domestic nuclear power plant has been suggested. It has reference value for nuclear power plant to analysis LPMS alarm reason. It's helpful to safety and economy of nuclear power plant. (author)
Additional details
Publishing Information
- Journal Title
- Nuclear Electronics and Detection Technology
- Journal Volume
- 35
- Journal Issue
- 7
- Journal Page Range
- p. 712-715, 720
- ISSN
- 0258-0934
INIS
- Country of Publication
- China
- Country of Input or Organization
- China
- INIS RN
- 50051320
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Descriptors DEI
- ALARM SYSTEMS; CHINA; COMPARATIVE EVALUATIONS; LOOSE PARTS MONITORING; MANAGEMENT; NUCLEAR POWER PLANTS; PERFORMANCE; PRIMARY COOLANT CIRCUITS; SAFETY
- Descriptors DEC
- ASIA; COOLING SYSTEMS; ENERGY SYSTEMS; EVALUATION; MONITORING; NUCLEAR FACILITIES; POWER PLANTS; REACTOR COMPONENTS; REACTOR COOLING SYSTEMS; THERMAL POWER PLANTS
Optional Information
- Notes
- 1 fig., 1 tabs.