Published 1997 | Version v1
Report Open

Under-reactor Room 305/2 of the unit 4 of Chernobyl 1 NPP: its state, fuel quantity evaluation

Description

The question of the quantity of the used up nuclear fuel in the under-reactor room is discussed. These are given the results of direct visual observation, TV-records and photographing in this room and their connection with the date of chemical analysis of core samples and dose rate measurement. On the basis of these results the detailed model of relative petitioning of the main elements in the volume space of the former active zone of the reactor is developed. The minimum quantity evaluation of nuclear fuel in the room 305/2 is given. 10 refs., 1 tab., 2 figs

Availability note (English)

Available from INIS in electronic form and/or on microfiche .

Files

29030566.pdf

Files (375.2 kB)

Name Size Download all
md5:cf1e25f36d7c66973fb492dbb803c28a
375.2 kB Preview Download

System files (37.8 kB)

Name Size Download all

Additional details

Additional titles

Original title (Russian)
Подаппаратное помещение 305/2 четвёртого блока Чернобыльской АЭС: его состояние, оценка количества топлива

Publishing Information

Imprint Pagination
11 p.