Published November 2003 | Version v1
Journal article

Advances in cardiac imaging

Creators

  • 1. Dept of Diagnostic Radiology, Univ. of Munich (Germany)

Description

Lower iodine concentration injected at a low flow rate (group 1=0.75 g/s iodine) resulted in acceptable contrast enhancement in 53.8% of the patients only. There was no significant difference between a lower concentration of contrast injected at a high flow rate and a high concentration of contrast injected at a low flow rate (groups 2 and 3 ∼1 g/s iodine). A high concentration of contrast agent administered with a high flow rates (group 4=1.4 g/s iodine) at times resulted in arterial blood CT density reaching above 350 HU, which interfered visually with coronary calcifications [2]. We concluded [3] that the injection of ∼1 g/s iodine results in an optimal (250-300 HU) contrast enhancement for cardiac MDCT (Fig. 1). (orig.)

Additional details

Publishing Information

Journal Title
European Radiology
Journal Volume
13
Journal Issue
3,Suppl
Journal Page Range
p. N50-N52
ISSN
0938-7994
CODEN
EURAE3

Conference

Title
15. European congress of radiology
Acronym
ECR 2003
Dates
7-11 Mar 2003
Place
Vienna (Austria)

INIS

Country of Publication
Germany
Country of Input or Organization
Germany
INIS RN
35022770
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference
Descriptors DEI
BLOOD; CARDIOVASCULAR DISEASES; COMPUTERIZED TOMOGRAPHY; CORONARIES; DENSITY; FLOW RATE; INJECTION; IODINE; NMR IMAGING; PATIENTS
Descriptors DEC
ARTERIES; BIOLOGICAL MATERIALS; BLOOD VESSELS; BODY; BODY FLUIDS; CARDIOVASCULAR SYSTEM; DIAGNOSTIC TECHNIQUES; DISEASES; ELEMENTS; HALOGENS; INTAKE; MATERIALS; NONMETALS; ORGANS; PHYSICAL PROPERTIES; TOMOGRAPHY