Published December 2018 | Version v1
Journal article

Measurement of Local Two-Phase Flow Parameters in an Annulus Under Low-Pressure Subcooled Boiling Condition

  • 1. Jeju Nat'l Univ., Jeju (Korea, Republic of)
  • 2. Chung-Ang Univ., Seoul (Korea, Republic of)

Description

In this study, an experimental investigation is performed to measure the local bubble parameters in steam-water subcooled boiling flow under atmospheric pressure conditions. The test section is a vertical concentric annulus with an effective height of 2 m, and optical fiber probes are used to measure various local bubble parameters during boiling of the subcooled flow. The local void fraction, mean bubble velocity, interfacial area density, and Sauter mean diameter are measured at four elevations, and their radial profiles are obtained by traversing the tip of optical probes. In the experiments, the flow conditions were set for a heat flux of 370 kW/m2, a mass flux of 430~680 kg/m2s, and an inlet subcooling of 12~18 K at pressures ranging from 114 to 152 kPa.

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
42
Journal Issue
12
Series
8 refs, 8 figs, 3 tabs
Journal Page Range
p. 813-824
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
50043617
Subject category
S42: ENGINEERING;
Descriptors DEI
BUBBLES; DENSITY; HEAT FLUX; PERFORMANCE; PROBES; SUBCOOLED BOILING; TWO-PHASE FLOW; VELOCITY; VOID FRACTION
Descriptors DEC
BOILING; FLUID FLOW; PHASE TRANSFORMATIONS; PHYSICAL PROPERTIES