Published 2007 | Version v1
Miscellaneous

Depth of interaction (DOI) determination in three-layer small animal PET

  • 1. Seoul National Univ. College of Medicine, Seoul (Korea, Republic of)

Description

Improved spatial resolution without sacrificing sensitivity is one of the most challenging developmental goals for small animal PET scanners. The 3-layer configuration that we propose here utilizes relative offsets of half a crystal pitch in x, y directions, and pulse shape discrimination to obtain DOI. We present recent progress in developing the 3-layer PET scanner with LGSO crystals and H9500 PMTs. 3-layers of crystals (of each crystal 1.5x1.5x7.0 mm3) were composed of a L0.2GSO crystal layer and a L0.9GSO crystal layer aligned with each other, and a L0.9GSO crystal layer offset at half a crystal pitch in x, y directions. The L0.2GSO crystal layer was attached to a Hamamatsu H9500. The devised small animal PET scanner has a diameter of 84 mm. We built a charge division circuit consisted of resistor matrix. Struck positions by photons were obtained with the 4 signals from the circuit. To study the layer identification capability of two crystal layers with a relative offset by half a crystal, we assembled two crystal layers with a 7x7 L0.9GSO crystal block and a 6x6 L0.9GSO crystal and obtained flood images at the center and the corner of the H9500 PMT. The crystal identification between the aligned L0.2GSO and L0.9GSO crystal layers was obtained using different pulse characteristics from these two crystals. The flood image of the 2-layer crystal blocks at the center and the corner of the H9500 PMT shows the clear separation of individual crystals and no distortion of image. The ratios of peaks to valleys of horizontal and vertical projection diagrams were about 5 ∼ 6(center) and 3 ∼ 4(corner). Energy resolutions were 14.4% (6x6 crystals) and 18.1% (7x7 crystals). We also achieved the crystal identification efficiencies of ∼99%. Based on these results, we are confident that a 3-layer animal PET scanner with high resolution and sensitivity can be built

Part of:
Proceedings of the Korean Society Nuclear Medicine Autumn Meeting 2007

Additional details

Publishing Information

Publisher
KSNM
Imprint Place
Seoul (Korea, Republic of)
Imprint Title
Proceedings of the Korean Society Nuclear Medicine Autumn Meeting 2007
Imprint Pagination
[512 p.]
Journal Page Range
[2 p.]

Conference

Title
46. Annual Autumn Meeting of the Korean Society Nuclear Medicine
Dates
26-27 Oct 2007
Place
Seoul (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
40105766
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
ANIMALS; IMAGES; POSITRON COMPUTED TOMOGRAPHY; SENSITIVITY; SPATIAL RESOLUTION
Descriptors DEC
COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; EMISSION COMPUTED TOMOGRAPHY; RESOLUTION; TOMOGRAPHY

Optional Information