Published December 1, 1999 | Version v1
Journal article

The analytical gas chromatographic system of the JET active gas handling system - tritium commissioning and use during DTE1

  • 1. Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking

Description

The analytical gas chromatographic system (AN-GC) was the main tool used to analyse gas mixtures from various subsystems of the active gas handling system (AGHS) and to characterise the functioning of the different processes during the deuterium-tritium experiment (DTE1). Samples were transferred to AN-GC via long 1/4'' lines. Calibration factors, accuracy and minimum detection limits for different gas species were determined for the thermal conductivity detectors, flame ionisation detectors and ionisation chambers. The performance of the AN-GC is discussed by means of various chromatograms and the experience gained with these detectors as well as their limits are mentioned. The AN-GC worked very reliably and about 320 analyses were performed during DTE1 and the subsequent cleanup phase. (orig.)

Additional details

Publishing Information

Journal Title
Fusion Engineering and Design
Journal Volume
47
Journal Issue
2-3
Journal Page Range
p. 333-353
ISSN
0920-3796
CODEN
FEDEEE

Optional Information

Notes
22 refs.