Published May 1977 | Version v1
Report Open

Fabrication of an improved tube-to-pipe header heat exchanger for the Fuel Failure Mockup (FFM) Facility

Description

The procedure used in fabricating an improved tube-to-pipe header heat exchanger for the Fuel Failure Mockup (FFM) Facility is described. Superior performance is accomplished at reduced cost with adherence to the ASME Boiler and Pressure Vessel Code. The techniques used and the method of fabrication are described in detail

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., PC A03/MF A01.

Files

8343976.pdf

Files (985.0 kB)

Name Size Download all
md5:8989d242c22cd4d6cd31c71c19ed37d1
985.0 kB Preview Download

Additional details

Additional titles

Augmented title (English)
LMFBR

Publishing Information

Imprint Pagination
20 p.
Report number
ORNL/TM--5733