Published May 1983 | Version v1
Journal article

Clinical evaluation of unsharp masking and slit scanning techniques in chest radiography

Description

Conventional, unsharp masking, and slitmask (combining slip radiography and unsharp masking) techniques were compared in a clinical nodule detection study in cancer patients who were at risk for metastatic lung disease. Unsharp masking improved detection rates for nodules located in poorly penetrated areas of the chest (25% vs. 52%), with no difference in detection rates for other areas of the image and no change in false-positive detection rates. Results with the slit-mask techniques did not differ significantly from those obtained with conventional techniques. In general, the differences in nodule detection rates noted between different techniques in the clinical study were less than had been observed in earlier phantom-nodule detection studies. Possible reasons for these findings are discussed

Additional details

Publishing Information

Journal Title
Radiology
Journal Volume
147
Journal Issue
2
Series
Radiology.
Journal Page Range
351-356
ISSN
0033-8419

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
15002212
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOMEDICAL RADIOGRAPHY; CHEST; DIAGNOSIS; IRRADIATION PROCEDURES; LUNGS; NEOPLASMS; PATIENTS
Descriptors DEC
BODY; BODY AREAS; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; ORGANS; RESPIRATORY SYSTEM