Clinical evaluation of unsharp masking and slit scanning techniques in chest radiography
Description
Conventional, unsharp masking, and slitmask (combining slip radiography and unsharp masking) techniques were compared in a clinical nodule detection study in cancer patients who were at risk for metastatic lung disease. Unsharp masking improved detection rates for nodules located in poorly penetrated areas of the chest (25% vs. 52%), with no difference in detection rates for other areas of the image and no change in false-positive detection rates. Results with the slit-mask techniques did not differ significantly from those obtained with conventional techniques. In general, the differences in nodule detection rates noted between different techniques in the clinical study were less than had been observed in earlier phantom-nodule detection studies. Possible reasons for these findings are discussed
Additional details
Publishing Information
- Journal Title
- Radiology
- Journal Volume
- 147
- Journal Issue
- 2
- Series
- Radiology.
- Journal Page Range
- 351-356
- ISSN
- 0033-8419
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 15002212
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- BIOMEDICAL RADIOGRAPHY; CHEST; DIAGNOSIS; IRRADIATION PROCEDURES; LUNGS; NEOPLASMS; PATIENTS
- Descriptors DEC
- BODY; BODY AREAS; DIAGNOSTIC TECHNIQUES; DISEASES; MEDICINE; ORGANS; RESPIRATORY SYSTEM