Published June 2014 | Version v1
Journal article

Comparing four volumetric modulated arc therapy beam arrangements for the treatment of early-stage prostate cancer

  • 1. School of Health Sciences, University of Newcastle, Callaghan, NSW (Australia)
  • 2. British Columbia Cancer Agency, Fraser Valley Centre, Surrey, BC (Canada)

Description

This study compared four different volumetric modulated arc therapy (VMAT) beam arrangements for the treatment of early-stage prostate cancer examining plan quality and the impact on a radiotherapy department's resources. Twenty prostate cases were retrospectively planned using four VMAT beam arrangements (1) a partial arc (PA), (2) one arc (1A), (3) one arc plus a partial arc (1A + PA) and (4) two arcs (2A). The quality of the dose distributions generated were compared by examining the overall plan quality, the homogeneity and conformity to the planning target volume (PTV), the number of monitor units and the dose delivered to the organs at risk. Departmental resources were considered by recording the planning time and beam delivery time. Each technique produced a plan of similar quality that was considered adequate for treatment; though some differences were noted. The 1A, 1A + PA and 2A plans demonstrated a better conformity to the PTV which correlated to improved sparing of the rectum in the 60–70 Gy range for the 1A + PA and 2A techniques. The time needed to generate the plans was different for each technique ranging from 13.1 min for 1A + PA to 17.8 min for 1A. The PA beam delivery time was fastest with a mean time of 0.9 min. Beam-on times then increased with an increase in the number of arcs up to an average of 2.2 min for the 2A technique. Which VMAT technique is best suited for clinical implementation for the treatment of prostate cancer may be dictated by the individual patient and the availability of departmental resources

Availability note (English)

Available from http://dx.doi.org/10.1002/jmrs.52; Available from http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4175844

Additional details

Publishing Information

Journal Title
Journal of Medical Radiation Sciences (Print)
Journal Volume
61
Journal Issue
2
Journal Page Range
p. 91-101
ISSN
2051-3895

INIS

Country of Publication
Australia
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
46108107
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BEAMS; DELIVERY; DOSES; HAZARDS; IMPLEMENTATION; NEOPLASMS; PATIENTS; PLANNING; PROSTATE; RADIATION DOSE DISTRIBUTIONS; RADIOTHERAPY; RECTUM
Descriptors DEC
BODY; DIGESTIVE SYSTEM; DISEASES; GASTROINTESTINAL TRACT; GLANDS; INTESTINES; LARGE INTESTINE; MALE GENITALS; MEDICINE; NUCLEAR MEDICINE; ORGANS; RADIOLOGY; THERAPY

Optional Information

Copyright
Copyright (c) 2014 The Authors. Journal of Medical Radiation Sciences published by Wiley Publishing Asia Pty Ltd on behalf of Australian Institute of Radiography and New Zealand Institute of Medical Radiation Technology.
Notes
PMCID: PMC4175844; PMID: 26229643; OAI: oai:pubmedcentral.nih.gov:4175844