Determination of uranium in ore with volumetry of H2SO4-TiCl3-NH4VO3

  • 1. Nanhua Univ., Hengyang (China). School of Architecture, Resources and Environment Engineering
  • 2. No.417 Team of Hunan Provincial Geology Exploration Bureau, Hengyang (China)

Description

The uranium ore sample is dissolved with H2SO4, HF and H2O2. Uranium (VI) is reduced to uranium (IV) by titanous. The excess titanous is oxidized with sodium nitrite and excess sodium nitrite is destroyed with urea. Uranium can be determined by ammonium vanadate volumetry in the medium of 6 mol/L sulfuric acid taking o-phenanthroline ferrous sulfate as indicators. The determination limit is 0.03%, the RSD is better than 3%, the recovery is 95-105%. The error is less than 2% compared with the standard sample of uranium ore

Additional details

Publishing Information

Journal Title
Uranium Mining and Metallurgy
Journal Volume
23
Journal Issue
3
Journal Page Range
p. 147-150
ISSN
1000-8063