Published August 1, 2003
| Version v1
Journal article
The facility for ATLAS resistive plate chambers assembly
Description
The dedicated facility built for the assembling of the nearly 1000 RPC units of the ATLAS μ-spectrometer is described in detail. The necessity of keeping the gravitational sagitta below 10 mm for the 5-m-long RPC units has driven the careful design of the extruded Al lateral profiles and suspension end-plates. A special assembly table allows to maintain the mechanical tolerances of each unit well below ±1 mm in all dimensions. Both gas gaps inside each unit are kept at a constant pressure of 103 Pa over the whole surface, in order to ensure the uniformity of the gap
Additional details
Identifiers
- PII
- S0168900203012890;
Publishing Information
- Journal Title
- Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
- Journal Volume
- 508
- Journal Issue
- 1-2
- Journal Page Range
- p. 116-119
- ISSN
- 0168-9002
- CODEN
- NIMAER
Conference
- Title
- 6. international workshop on resistive plate chambers and related detectors
- Dates
- 26-27 Nov 2001
- Place
- Coimbra (Portugal)
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- International Atomic Energy Agency (IAEA)
- INIS RN
- 35021548
- Subject category
- S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S43: PARTICLE ACCELERATORS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- DESIGN; MECHANICAL PROPERTIES; MUON DETECTION; PARTICLE DISCRIMINATION; SPECIFICATIONS; SPECTROMETERS
- Descriptors DEC
- CHARGED PARTICLE DETECTION; DETECTION; MEASURING INSTRUMENTS; PARTICLE IDENTIFICATION; RADIATION DETECTION
Optional Information