Published August 1, 2003 | Version v1
Journal article

The facility for ATLAS resistive plate chambers assembly

Description

The dedicated facility built for the assembling of the nearly 1000 RPC units of the ATLAS μ-spectrometer is described in detail. The necessity of keeping the gravitational sagitta below 10 mm for the 5-m-long RPC units has driven the careful design of the extruded Al lateral profiles and suspension end-plates. A special assembly table allows to maintain the mechanical tolerances of each unit well below ±1 mm in all dimensions. Both gas gaps inside each unit are kept at a constant pressure of 103 Pa over the whole surface, in order to ensure the uniformity of the gap

Additional details

Identifiers

PII
S0168900203012890;

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research. Section A, Accelerators, Spectrometers, Detectors and Associated Equipment
Journal Volume
508
Journal Issue
1-2
Journal Page Range
p. 116-119
ISSN
0168-9002
CODEN
NIMAER

Conference

Title
6. international workshop on resistive plate chambers and related detectors
Dates
26-27 Nov 2001
Place
Coimbra (Portugal)

INIS

Country of Publication
Netherlands
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
35021548
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY; S43: PARTICLE ACCELERATORS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DESIGN; MECHANICAL PROPERTIES; MUON DETECTION; PARTICLE DISCRIMINATION; SPECIFICATIONS; SPECTROMETERS
Descriptors DEC
CHARGED PARTICLE DETECTION; DETECTION; MEASURING INSTRUMENTS; PARTICLE IDENTIFICATION; RADIATION DETECTION

Optional Information

Copyright
Copyright (c) 2003 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.