Study of chemical cleaning technique for removing sludge in secondary side of PWR SG

  • 1. Academia Sinica, Beijing, BJ (China). Inst. of Atomic Energy

Description

The effect of components, concentration, pH, temperature, cleaning time and flowrate of chemical cleaning solvent made from EDTA mainly on Fe3O4 solubility and corrosion rate of A3 carbon steel, S271 low alloy steel and 800 alloy are introduced. A small chemical cleaning test loop (30L) was built to study the cleaning technique. The effect of residue of chemical cleaning solvent on anti-corrosion performance of materials has been studied under the simulation condition of PWR (pressure water reactor) SG (steam generator) secondary side. The results show that the chemical solvent (pH = 7, 10% EDTA, 1% assistance solvent and 0.25% inhibitor A) can dissolve Fe3O4 18 ∼23 g/L under the conditions of 93 +- 5 degree C, 8 hours and 112 r/min (1.8 ∼ 2.0 t/h). The corrosion rate of material is low. When the residue of EDTA is less than 0.01% there is no impact on the anti-corrosion performance of materials in PWR SG secondary side at normal operation condition (260 +- 5 degree C)

Availability note (English)

MF available from INIS under the Report Number.

Files

26050578.pdf

Files (494.0 kB)

Name Size Download all
md5:b8541f4610cb3be57ac30caaa7fe8ff9
494.0 kB Preview Download

Additional details

Publishing Information

ISBN
7-5022-1113-6
Imprint Pagination
14 p.
Report number
CNIC--00806

Optional Information

Secondary number(s)
IAE--0129.