Using predictive maintenance methods at Hanford Engineering Development Laboratory (HEDL) to increase equipment availability and reduce overall managed costs
Description
This paper describes the predictive maintenance program that is presently in place at Hanford Engineering Development Laboratory using vibration analysis and oil sampling techniques. A pilot program at the Fast Flux Test Facility (FFTF) has been established using reliability-based maintenance concepts such as trend and failure analysis techniques. The first system being analyzed at FFTF will be the electrical distribution system. 2 figs
Availability note (English)
MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 - OSTI; 1 as DE89010140.
Files
Additional details
Publishing Information
- Imprint Pagination
- 8 p.
- Report number
- HEDL-SA--3581
Conference
- Title
- DOE-wide maintenance management conference.
- Dates
- 25-29 Aug 1986.
- Place
- Denver, CO (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 20061301
- Subject category
- S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COST; FAILURES; FFTF REACTOR; HANFORD RESERVATION; MANAGEMENT; REACTOR MAINTENANCE
- Descriptors DEC
- EPITHERMAL REACTORS; FAST REACTORS; LIQUID METAL COOLED REACTORS; MAINTENANCE; NATIONAL ORGANIZATIONS; REACTORS; RESEARCH AND TEST REACTORS; RESEARCH REACTORS; SODIUM COOLED REACTORS; TEST FACILITIES; TEST REACTORS; US DOE; US ORGANIZATIONS
Optional Information
- Notes
- Portions of this document are illegible in microfiche products.
- Secondary number(s)
- CONF-8608241--1.