Published 1988 | Version v1
Journal article

The quality factor for neutrons in radiation protection: physical parameters

  • 1. Wuerzburg Univ. (Germany, F.R.). Inst. fuer Medizinische Strahlenkunde

Description

Recommendations by NCRP and ICRP for a selective increase of the quality factor for neutrons have not been implemented in the practice of radiation protection, but have added urgency to the search for a more consistent new convention on quality factors. In response to this need, a liaison group of ICRP and ICRU has proposed numerical changes, but also a replacement of the reference parameter LET by the microdosimetric variable lineal energy. This would make quality factors and dose equivalents measurable, but would make computations more complicated. To resolve the dilemma, it is proposed to use an equivalence relation between lineal energy and LET which leads to nearly identical definitions whenever one deals with charged particles of sufficiently long range. For photons below 200 keV and for neutrons below 0.5 MeV, the equivalence is imperfect, but it may, even in these cases, be acceptable for the practical purposes of radiation protection. (author)

Additional details

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
23
Journal Issue
1-4
Series
Radiat. Prot. Dosim.
Journal Page Range
73-78
ISSN
0144-8420
CODEN
RPDOD

Conference

Title
6. symposium on neutron dosimetry.
Dates
12-16 Oct 1987.
Place
Neuherberg (Germany, F.R.).

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
20029391
Subject category
S63: RADIATION, THERMAL, AND OTHER ENVIRONMENTAL POLLUTANT EFFECTS ON LIVING ORGANISMS AND BIOLOGICAL MATERIALS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
DOSE EQUIVALENTS; ENERGY DEPENDENCE; LET; NEUTRON DOSIMETRY; QUALITY FACTOR; RADIATION PROTECTION
Descriptors DEC
DOSIMETRY; ENERGY TRANSFER

Optional Information

Contract/Grant/Project number
Contract St. Sch. 1002