Published 1981
| Version v1
Journal article
Modular first wall concept for steady state operation
Description
On the basis of the limiter design proposed for ZEPHYR a first wall concept has been developed which can also be used as a large area limiter, heat shield or beam pump. Its specific feature is the thermal contact of the wall armour elements with the water-cooled base plates. The combination of radiation and contact cooling, compared with radiation only, helps to lower the steady state temperatures of the first wall by approximately 50 % and to reduce the cooling-time between discharges. Particulary the lower wall temperature give a larger margin for additional heating of the wall by plasma disruption or neutral beams until excessive erosion or damage of the armour takes place
Additional details
Publishing Information
- Journal Title
- Proc. Symp. Eng. Probl. Fusion Res.
- Journal Issue
- p. 1626-1629
- Series
- Proc. Symp. Eng. Probl. Fusion Res.
- ISSN
- 0145-5958
Conference
- Title
- 9. symposium on engineering problems of fusion research.
- Dates
- 26-29 Oct 1981.
- Place
- Chicago, IL (USA).
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 14789846
- Subject category
- S70: PLASMA PHYSICS AND FUSION TECHNOLOGY;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- COOLING; FIRST WALL; HEAT TRANSFER; MODULAR STRUCTURES; SPECIFICATIONS; STEADY-STATE CONDITIONS; TOKAMAK DEVICES
- Descriptors DEC
- CLOSED PLASMA DEVICES; ENERGY TRANSFER; THERMONUCLEAR DEVICES; THERMONUCLEAR REACTOR WALLS
Optional Information
- Secondary number(s)
- CONF-811040--.