Time projection Compton spectrometer (TPCS)

Description

We present a new technique for measuring the energy spectrum of X rays emitted by high-intensity, medium-voltage flash x-ray sources. The method sorts Compton electrons by drift velocity time-of-flight in a non-uniform magnetic field. We explain the conceptual design of the spectrometer, show how we have modeled it using Monte Carlo methods, and discuss the procedure for unfolding x-ray spectrum information from electron time-of-flight data. The technique appears promising, especially for short-pulse x-ray sources

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS, PC A02/MF A01 as DE86012950.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
24 p.
Report number
SAND--86-0357C

Conference

Title
23. annual conference on nuclear and space radiation effects.
Dates
20-23 Jul 1986.
Place
Providence, RI (USA).

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
18002792
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
COMPTON SPECTROMETERS; COMPUTERIZED SIMULATION; MONTE CARLO METHOD; SPECIFICATIONS; SPECTRA UNFOLDING; TIME-OF-FLIGHT METHOD; X-RAY SPECTROSCOPY
Descriptors DEC
DATA PROCESSING; GAMMA SPECTROMETERS; MEASURING INSTRUMENTS; SIMULATION; SPECTROMETERS; SPECTROSCOPY

Optional Information

Secondary number(s)
CONF-860706--13.