Published May 2010 | Version v1
Journal article

Measurement of coronary flow response to cold pressor stress in asymptomatic women with cardiovascular risk factors using spiral velocity-encoded cine MRI at 3 Tesla

  • 1. Dept. of Radiology, Univ. of Texas Southwestern Medical Center, Dallas, TX (United States)
  • 2. Dept. of Internal Medicine, Univ. of Texas Southwestern Medical Center, Dallas, TX (United States)
  • 3. Dept. of Philips Medical Systems, Cleveland, OH (United States)

Description

Background: Coronary sinus (CS) flow in response to a provocative stress has been used as a surrogate measure of coronary flow reserve, and velocity-encoded cine (VEC) magnetic resonance imaging (MRI) is an established technique for measuring CS flow. In this study, the cold pressor test (CPT) was used to measure CS flow response because it elicits an endothelium-dependent coronary vasodilation that may afford greater sensitivity for detecting early changes in coronary endothelial function. Purpose: To investigate the feasibility and reproducibility of CS flow reactivity (CSFR) to CPT using spiral VEC MRI at 3 Tesla in a sample of asymptomatic women with cardiovascular risk factors. Material and Methods: Fourteen asymptomatic women (age 38 years ± 10) with cardiovascular risk factors were studied using 3D spiral VEC MRI of the CS at 3 T. The CPT was utilized as a provocative stress to measure changes in CS flow. CSFR to CPT was calculated from the ratio of CS flow during peak stress to baseline CS flow. Results: CPT induced a significant hemodynamic response as measured by a 45% increase in rate-pressure product (P<0.01). A significant increase in CS volume flow was also observed (baseline, 116 ± 26 ml/min; peak stress, 152 ± 34 ml/min, P=0.01). CSFR to CPT was 1.31 ± 0.20. Test-retest variability of CS volume flow was 5% at baseline and 6% during peak stress. Conclusion: Spiral CS VEC MRI at 3 T is a feasible and reproducible technique for measuring CS flow in asymptomatic women at risk for cardiovascular disease. Significant changes in CSFR to CPT are detectable, without demanding pharmacologic stress.

Additional details

Publishing Information

Journal Title
Acta Radiologica (online)
Journal Volume
51
Journal Issue
4
Journal Page Range
p. 420-426
ISSN
1600-0455

INIS

Country of Publication
Sweden
Country of Input or Organization
Sweden
INIS RN
41061623
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BIOLOGICAL STRESS; BLOOD FLOW; CARDIOVASCULAR DISEASES; HEART; HELICAL CONFIGURATION; NMR IMAGING; VEINS
Descriptors DEC
BLOOD VESSELS; BODY; CARDIOVASCULAR SYSTEM; CONFIGURATION; DIAGNOSTIC TECHNIQUES; DISEASES; ORGANS