Published March 1, 1990 | Version v1
Journal article

Silicon detector developments for calorimetry: Technology and radiation damage

  • 1. Hamburg Univ. (Germany, F.R.). 1. Inst. fuer Experimentalphysik

Description

Large area silicon detectors with a sensitive area of 5x5 cm2 and a thickness of 400 μm have been developed for the instrumentation of the plug calorimeter at H1/HERA. The novel method, a combination of surface barrier and planar processes, has resulted in detectors with excellent quality and long term operation stability. A current density of down to 1 nA/cm2 was reached. Studies of radiation damage produced by 14 MeV neutrons, 25 MeV protons and 20 keV X-rays were performed and the resulting current increase, impurity removal and charge collection deficiency investigated. Long term storage and short term heat treatments showed appreciable annealing effects by up to 94%. (orig.)

Additional details

Publishing Information

Journal Title
Nuclear Instruments and Methods in Physics Research, Section A
Journal Volume
288
Journal Issue
1
Series
Nucl. Instrum. Methods Phys. Res., Sect. A.
Journal Page Range
1-12
ISSN
0168-9002
CODEN
NIMAE

Conference

Title
New developments on radiation detectors.
Acronym
5. European symposium on semiconductor detectors
Dates
21-23 Feb 1989.
Place
Muenchen (Germany, F.R.).