Published 1988 | Version v1
Report

Design of the forward RICH counter in DELPHI and results from operation of a full-scale prototype

  • 1. National Research Centre for the Physical Sciences Democritos, Athens (Greece)
  • 2. Institute of Nuclear Physics, Cracow (Poland)
  • 3. Niels Bohr Inst., Copenhagen (Denmark)

Description

For e/π/K/p particle identification in DELHI the Ring Imaging Cherenkov (RICH) counter is constructed at CERN. The detector design and test results of full-scale detector prototype with different gaseous filling are given. 7 refs.; 7 figs.; 1 tab

Additional details

Additional titles

Original title (no language)
Mezhdunarodnyj simpozium po koordinatnym detektoram v fizike vysokikh ehnergij. Trudy.

Publishing Information

Imprint Title
International symposium on position detectors in high energy physics. Proceedings
Imprint Pagination
404 p.
Journal Page Range
p. 286-298.
Report number
JINR-D--1-13-88-172

Conference

Title
International symposium on position detectors in high energy physics.
Dates
22-25 Sep 1987.
Place
Dubna (USSR).

INIS

Country of Publication
USSR
Country of Input or Organization
USSR
INIS RN
21003393
Subject category
S46: INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND TECHNOLOGY;
Resource subtype / Literary indicator
Conference
Descriptors DEI
ANGULAR DISTRIBUTION; CHERENKOV COUNTERS; FUNCTIONAL MODELS; GASES; MULTIWIRE PROPORTIONAL CHAMBER; PARTICLE IDENTIFICATION; PERFORMANCE TESTING
Descriptors DEC
DISTRIBUTION; FLUIDS; MEASURING INSTRUMENTS; PROPORTIONAL COUNTERS; RADIATION DETECTORS; TESTING

Optional Information

Notes
Imprint:Mezhdunarodnyj simpozium po koordinatnym detektoram v fizike vysokikh ehnergij. Trudy.