The Performance Estimation of PHTS Pump of DSFR

  • 1. Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

Description

In order to estimate the hydraulic behavior of the PHTS pump in sodium environment, model tests were conducted in water experimental facility by SAMJIN Industrial Co. before model tests using the STELLA-1 with sodium environment in 2015. STELLA-1 (Sodium inTegral Effect test Loop for safety simuLation and Assessment) is a large-scale separate effect test facility for demonstrating the thermal-hydraulic performances of major components such as a Sodium-to-Sodium heat exchanger (DHX), Sodium-to-Air heat exchanger (AHX) of the decay heat removal system, and mechanical sodium pump of the primary heat transport system (PHTS), which are important to ensure the safety of the sodium-cooled fast reactor (SFR). When the model and the prototype have the same the flow coefficient, to maintaining the dynamic similarity both model and prototype the non-dimensional coefficients to be simulated are head coefficient and power coefficient

Part of:
Proceedings of the KNS 2015 Spring Meeting

Additional details

Publishing Information

Publisher
KNS
Imprint Place
Daejeon (Korea, Republic of)
Imprint Title
Proceedings of the KNS 2015 spring meeting
Imprint Pagination
[1 CD-ROM]
Journal Page Range
[3 p.]

Conference

Title
2015 spring meeting of the KNS
Dates
6-8 May 2015
Place
Jeju (Korea, Republic of)

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
47023010
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
AFTER-HEAT REMOVAL; COMPUTERIZED SIMULATION; DYNAMICS; HEAT EXCHANGERS; HYDRAULICS; PERFORMANCE; PUMPS; SAFETY; SODIUM COOLED REACTORS; TEST FACILITIES; THERMAL HYDRAULICS
Descriptors DEC
EQUIPMENT; FLUID MECHANICS; HYDRAULICS; LIQUID METAL COOLED REACTORS; MECHANICS; REACTORS; REMOVAL; SIMULATION

Optional Information

Notes
2 refs, 6 figs, 1 tab