Published October 1993
| Version v1
Miscellaneous
A sipping system for irradiated fuel elements diagnostic
Creators
- 1. Coordenadoria para Projetos Especiais (COPESP), Sao Paulo, SP (Brazil)
Description
This paper presents a wet-sipping system for quick diagnosis of irradiated fuel elements. Gamma detection is equated with respect to counting rate and system global efficiency. The theoretical results are verified by an experimental simulation employing NaI (Tl) and HPGe detectors in a I-131 activated water tank. The tank volume is parameterized for dimensioning to reach a minimum sensitivity of 600 Bq/l for gamma rays of 364 keV. It is found that the HPGe is the detector type which best suits the resolution requirement for a sipping system. (author)
Additional details
Additional titles
- Original title (Portuguese)
- Sistema de sipping para diagnostico de elementos combustiveis irradiados
Publishing Information
- Imprint Title
- Proceedings of the 9. Brazilian Meeting on Reactor Physics and Thermal Hydraulics
- Imprint Pagination
- 559 p.
- Journal Page Range
- p. 455-459.
Conference
- Title
- 9. Brazilian Meeting on Reactor Physics and Thermal Hydraulics.
- Dates
- 25-29 Oct 1993.
- Place
- Caxambu, MG (Brazil).
INIS
- Country of Publication
- Brazil
- Country of Input or Organization
- Brazil
- INIS RN
- 25010544
- Subject category
- S22: GENERAL STUDIES OF NUCLEAR REACTORS;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- ACCIDENTS; FAILED ELEMENT DETECTION; FUEL ELEMENTS; FUEL INTEGRITY; LEAKS; NUCLEAR FUELS; POST-IRRADIATION EXAMINATION; REACTOR SAFETY; SIMULATION; SPENT FUEL ELEMENTS
- Descriptors DEC
- DETECTION; ENERGY SOURCES; FUELS; MATERIALS; REACTOR COMPONENTS; REACTOR MATERIALS; SAFETY
Optional Information
- Notes