Published January 1993 | Version v1
Journal article

Application of carbon-11 labelled nicotine in the measurement of human cerebral blood flow and other physiological parameters

  • 1. National Center of Neurology and Psychiatry, Kodaira City, Tokyo (Japan). Dept. of Neurology
  • 2. Nippon Medical School, Tokyo (Japan)
  • 3. National Nakano Chest Hospital, Tokyo (Japan)

Description

Using positron emission tomography (PET), we measured the regional cerebral blood flow (rCBF) in five normal human subjects after intravenous injection of carbon-11 labelled (R)nicotine. The rCBF of the same subjects was measured by PET using the C15O2 inhalation steady-state method. The distribution of 11C activity in the brain after injection of 11C-(R)nicotine was almost equivalent to the CBF image obtaines with C15O2 inhalation steady-state method. The kinetics of 11C-(R)nicotine in the brain was analysed using a two-compartment model consisting of vascular and brain tissue compartments. The rCBF values obtained with 11C-(R)nicotine were higher than with C15O2 gas. It is possible that the relatively long fixed distribution of 11C-(R)nicotine with a short uptake period allows stimulation studies by measurement of CBF to be performed with better photon flux and a longer imaging time than are possible with H215O. (orig.)

Additional details

Publishing Information

Journal Title
European Journal of Nuclear Medicine
Journal Volume
20
Journal Issue
1
Journal Page Range
p. 46-52.
ISSN
0340-6997
CODEN
EJNMD9