A Normetex Model 15 M3/Hr Water Vapor Pumping Test
Description
Tests were performed using a Model 15 m3/hr Normetex vacuum pump to determine if pump performance degraded after pumping a humid gas stream. An air feed stream containing 30% water vapor was introduced into the pump for 365 hours with the outlet pressure of the pump near the condensation conditions of the water. Performance of the pump was tested before and after the water vapor pumping test and indicated no loss in performance of the pump. The pump also appeared to tolerate small amounts of condensed water of short duration without increased noise, vibration, or other adverse indications. The Normetex pump was backed by a dual-head diaphragm pump which was affected by the condensation of water and produced some drift in operating conditions during the test.
Availability note (English)
Available from http://sti.srs.gov/fulltext/SRNL-STI-2010-00070.pdf; PURL: https://www.osti.gov/servlets/purl/1001189-9orGP8/Additional details
Identifiers
Publishing Information
- Imprint Pagination
- 5 p.
- Report number
- SRNL-STI--2010-00070
Conference
- Title
- 9. International Conference on Tritium Science and Technology
- Acronym
- TRITIUM 2010
- Dates
- 24-29 Oct 2010
- Place
- Nara (Japan)
INIS
- Country of Publication
- United States
- Country of Input or Organization
- United States
- INIS RN
- 42010066
- Subject category
- S07: ISOTOPES AND RADIATION SOURCES; S42: ENGINEERING;
- Resource subtype / Literary indicator
- Conference, Non-conventional Literature
- Descriptors DEI
- HUMIDITY; PERFORMANCE TESTING; PUMPING; TRITIUM; VACUUM PUMPS
- Descriptors DEC
- BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; EQUIPMENT; HYDROGEN ISOTOPES; ISOTOPES; LABORATORY EQUIPMENT; LIGHT NUCLEI; MOISTURE; NUCLEI; ODD-EVEN NUCLEI; PUMPS; RADIOISOTOPES; TESTING; YEARS LIVING RADIOISOTOPES
Optional Information
- Contract/Grant/Project number
- AC09-08SR22470
- Funding organization
- US Department of Energy (United States)