Published December 20, 2010 | Version v1
Report

A Normetex Model 15 M3/Hr Water Vapor Pumping Test

Description

Tests were performed using a Model 15 m3/hr Normetex vacuum pump to determine if pump performance degraded after pumping a humid gas stream. An air feed stream containing 30% water vapor was introduced into the pump for 365 hours with the outlet pressure of the pump near the condensation conditions of the water. Performance of the pump was tested before and after the water vapor pumping test and indicated no loss in performance of the pump. The pump also appeared to tolerate small amounts of condensed water of short duration without increased noise, vibration, or other adverse indications. The Normetex pump was backed by a dual-head diaphragm pump which was affected by the condensation of water and produced some drift in operating conditions during the test.

Availability note (English)

Available from http://sti.srs.gov/fulltext/SRNL-STI-2010-00070.pdf; PURL: https://www.osti.gov/servlets/purl/1001189-9orGP8/

Additional details

Publishing Information

Imprint Pagination
5 p.
Report number
SRNL-STI--2010-00070

Conference

Title
9. International Conference on Tritium Science and Technology
Acronym
TRITIUM 2010
Dates
24-29 Oct 2010
Place
Nara (Japan)

INIS

Country of Publication
United States
Country of Input or Organization
United States
INIS RN
42010066
Subject category
S07: ISOTOPES AND RADIATION SOURCES; S42: ENGINEERING;
Resource subtype / Literary indicator
Conference, Non-conventional Literature
Descriptors DEI
HUMIDITY; PERFORMANCE TESTING; PUMPING; TRITIUM; VACUUM PUMPS
Descriptors DEC
BETA DECAY RADIOISOTOPES; BETA-MINUS DECAY RADIOISOTOPES; EQUIPMENT; HYDROGEN ISOTOPES; ISOTOPES; LABORATORY EQUIPMENT; LIGHT NUCLEI; MOISTURE; NUCLEI; ODD-EVEN NUCLEI; PUMPS; RADIOISOTOPES; TESTING; YEARS LIVING RADIOISOTOPES

Optional Information

Contract/Grant/Project number
AC09-08SR22470
Funding organization
US Department of Energy (United States)