This document was prepared to provide evaluations and recommendations regarding nondestructive evaluation methods that might be used to determine cracks and bowing in the ceiling of waste storage tanks on the Hanford site. The goal was to determine cracks as small as 1/16 in. wide in the ceiling, and bowing as small as 0.25 in. This report describes digital video camera methods that can be used to detect a crack in the ceiling of the dome, and methods for determining the surface topography of the ceiling in the waste storage tanks to detect localized movements in the surface. A literature search, combined with laboratory testing, comprised this study.

Availability note (English)

Available from http://www.pnl.gov/main/publications/external/technical_reports/PNNL-19113.pdf; PURL: https://www.osti.gov/servlets/purl/989034-3FoxCA/

Additional details

Publishing Information

Imprint Pagination
vp.
Report number
PNNL--19113

Optional Information

Contract/Grant/Project number
EY4049110; AC05-76RL01830
Notes
doi 10.2172/989034
Funding organization