Published December 18, 2002 | Version v1
Journal article

New beam position monitor system design for the APS injector

  • 1. Advanced Photon Source, Argonne National Laboratory, 9700 South Cass Avenue, Argonne, Illinois 60439 (United States)

Description

Demands on the APS injector have evolved over the last few years to the point that an upgrade to the existing beam position monitor (BPM) electronics is required. The injector is presently being used as a source for both the low-energy undulator test line (LEUTL) project and the top-up mode of operation. These new requirements and the fact that many new rf receiver components are available at reasonable cost make this upgrade very desirable at this time. The receiver topology selected is a logarithmic processor, which is designed around the Analog Devices AD8313 log amplifier demodulation chip. This receiver will become the universal replacement for all injector applications measuring positions signals from 352 to 2856 MHz with minimum changes in hardware and without the use of a downconverter. The receiver design features integrated front-end gain and built-in self test. The data acquisition being considered at this time is a 100-MHz, 12-bit transient recorder digitizer. The latest experimental and commissioning data and results will be presented

Additional details

Identifiers

Publishing Information

Journal Title
AIP Conference Proceedings
Journal Volume
648
Journal Issue
1
Journal Page Range
p. 401-408
ISSN
0094-243X
CODEN
APCPCS

Conference

Title
10. beam instrumentation workshop
Dates
6-9 May 2002
Place
Upton, NY (United States)

Optional Information

Notes
(c) 2002 American Institute of Physics