Published 2010 | Version v1
Journal article

The effects of body posture, anatomy, age and pregnancy on the calculation of induced current densities at 50 Hz

  • 1. Health Protection Agency, Radiation Protection Div., Chilton, Didcot, Oxon OX11 0RQ (United Kingdom)

Description

This paper presents calculations of the induced current density in the body at 50 Hz from applied electric and magnetic fields. An extensive ensemble of 25 voxel models has been used to investigate the effects of body posture, anatomy, age and pregnancy. This set includes six adult models, eight child models and seven pregnant female models at various stages of gestation. The four postures investigated in the HPA adult model, NORMAN, were the standard position with the arms at the side, with the arms vertically above the head, the arms horizontally to the side and sitting. (authors)

Availability note (English)

Available from doi: http://dx.doi.org/10.1093/rpd/ncp285

Additional details

Identifiers

Publishing Information

Journal Title
Radiation Protection Dosimetry
Journal Volume
139
Journal Issue
4
Journal Page Range
p. 532-538
ISSN
0144-8420

Optional Information

Notes
22 refs