Published January 1992 | Version v1
Journal article

A standardized multifield irradiation technique for breast tumours using asymmetrical collimators and beam angulation

  • 1. University Hospital, Utrecht (Netherlands). Dept. of Radiotherapy

Description

Combined angulation and asymmetrical collimator matching techniques are used for field alignment in breast irradiation. A local regional irradiation technique has been developed that allows a uniform dose distribution to the entire target volume. The localization is characterized by simple measurement of a few patient co-ordinates. The equipment settings to produce a theoretical exact field alignment are calculated by a special computer program. These settings guide the simulation. We have designed the method such that the technique is standardized for all patients receiving breast and lymph node irradiation. This allows an easy, accurate and fast patient throughput at the simulator and accelerators. (author)

Additional details

Publishing Information

Journal Title
British Journal of Radiology
Journal Volume
65
Journal Issue
769
Series
Br. J. Radiol.
Journal Page Range
56-62
ISSN
0007-1285
CODEN
BJRAA

INIS

Country of Publication
United Kingdom
Country of Input or Organization
United Kingdom
INIS RN
23031054
Subject category
S62: RADIOLOGY AND NUCLEAR MEDICINE;
Descriptors DEI
BEAM POSITION; COLLIMATORS; COMPUTERIZED SIMULATION; MAMMARY GLANDS; PLANNING; RADIOTHERAPY; SPATIAL DOSE DISTRIBUTIONS
Descriptors DEC
BODY; DISTRIBUTION; GLANDS; MEDICINE; ORGANS; RADIATION DOSE DISTRIBUTIONS; SIMULATION; SPATIAL DISTRIBUTION; THERAPY