Published March 1, 2021 | Version v1
Journal article

Monte Carlo simulation of the MTS-N (LiF:Mg,Ti) relative response in function of the photon energy

  • 1. Centro de Desenvolvimento da Tecnologia Nuclear – CDTN/CNEN, Av. Presidente Antônio Carlos, 6627, 31270-901, Pampulha, Belo Horizonte (Brazil)

Description

We performed MCNPX simulations and experimental measurements to determine the relative energy response of MTS-N detectors. The energy spectra simulated were monoenergetic beams (from 20 keV to 250 keV), X-rays beams (N and RQR), 137Cs and 60Co gamma radiation. Experimental measurements were made with groups of MTS-N detectors irradiated with standardized 137Cs gamma radiation beams and continuous X-ray beams (N and RQR quality). Relative intrinsic efficiencies were calculated combining the MCNPX simulations and experimental measurements. Our results showed a good agreement with other studies using LiF detectors and the same radiation qualities. (paper)

Availability note (English)

Available from http://dx.doi.org/10.1088/1742-6596/1826/1/012050

Additional details

Publishing Information

Journal Title
Journal of Physics. Conference Series (Online)
Journal Volume
1826
Journal Issue
1
Journal Page Range
[10 p.]
ISSN