Evaluation of a method for correction of scatter radiation in thorax cone beam CT
Creators
- 1. CEA Grenoble (DTBS/STD), Lab. d'Electronique et de Technologie de l'Informatique, LETI, 38 (France)
- 2. European Synchrotron Radiation Facility (ESRF), 38 - Grenoble (France)
Description
Purpose: Cone beam CT (CBCT) enables three-dimensional imaging with isotropic resolution. X-ray scatter estimation is a big challenge for quantitative CBCT imaging of thorax: scatter level is significantly higher on cone beam systems compared to collimated fan beam systems. The effects of this scattered radiation are cupping artefacts, streaks, and quantification inaccuracies. The beam stops conventional scatter estimation approach can be used for CBCT but leads to a significant increase in terms of dose and acquisition time. At CEA-LETI has been developed an original scatter management process without supplementary acquisition. Methods and Materials: This Analytical Plus Indexing-based method (API) of scatter correction in CBCT is based on scatter calibration through offline acquisitions with beam stops on lucite plates, combined to an analytical transformation issued from physical equations. This approach has been applied with success in bone densitometry and mammography. To evaluate this method in CBCT, acquisitions from a thorax phantom with and without beam stops have been performed. To compare different scatter correction approaches, Feldkamp algorithm has been applied on rough data corrected from scatter by API and by beam stops approaches. Results: The API method provides results in good agreement with the beam stops array approach, suppressing cupping artefact. Otherwise influence of the scatter correction method on the noise in the reconstructed images has been evaluated. Conclusion: The results indicate that the API method is effective for quantitative CBCT imaging of thorax. Compared to a beam stops array method it needs a lower x-ray dose and shortens acquisition time. (authors)
Availability note (English)
Available from INIS in electronic formFiles
36026516.pdf
Files
(1.0 MB)
| Name | Size | Download all |
|---|---|---|
|
md5:268b3178553b66373e1007baebc6aebd
|
1.0 MB | Preview Download |
Additional details
Additional titles
- Original title (English)
- Evaluation d'une methode de correction du rayonnement diffuse en tomographie du thorax avec faisceau conique
Publishing Information
- Imprint Pagination
- 4 p.
- Report number
- INIS-FR--3208
Conference
- Title
- European congress of radiology
- Dates
- 4-8 Mar 2005
- Place
- Vienna (Austria)
INIS
- Country of Publication
- France
- Country of Input or Organization
- France
- INIS RN
- 36026516
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Resource subtype / Literary indicator
- Conference
- Descriptors DEI
- CAT SCANNING; CHEST; CORRECTIONS; IMAGE PROCESSING; OSTEODENSITOMETRY; RADIATION SCATTERING ANALYSIS
- Descriptors DEC
- BIOMEDICAL RADIOGRAPHY; BODY; CHEMICAL ANALYSIS; COMPUTERIZED TOMOGRAPHY; DIAGNOSTIC TECHNIQUES; MEDICINE; NONDESTRUCTIVE ANALYSIS; NUCLEAR MEDICINE; PROCESSING; RADIOLOGY; TOMOGRAPHY