Published June 1982 | Version v1
Journal article

Thermal-hydraulic characteristics of pressurized water reactors during commercial operation. Pt. 3

  • 1. Electricite de France, 93 - Saint-Denis. Dept. Fonctionnement des Centrales
  • 2. California Univ., Los Angeles (USA). Dept. of Chemical, Nuclear, and Thermal Engineering

Description

Two transients, an open grid and a scram at 50% load, were conducted on unit 4 of the PWR power plant Bugey. The thermal hydraulic response of the steam generator was recorded. For the open grid test, the following observations are noted: no alarming phenomena are observed in the steam generator during the transient. Primary pressure oscillations were very mild, and did not exceed about 4.8 bar/min with a maximum amplitude of +-8 bar. This condition should not result in significant stress levels. Steam generator outer shell metal temperature gradients remained within very acceptable limits; a maximum amplitude of about +130C and a rate not exceeding 0.8% C/min are obtained. This slow rate is explained by a fall in primary water temperature that allows for a temperature decrease inside the U-tube bundle. Similarly, the temperature rise on the tube sheet does not exceed an amplitude of 200C with a rate of about 20C/min. Again these conditions do not lead to any significant thermal shock on the tube sheet. The steam generator feed controls maintain the level within the normal operation range and the small addition of colder feedwater does not lead to great temperature changes because of the large mass of the recirculation water in the steam generator. For the scram at 50% load, the following observations are noted: no severe thermal or pressure transients are observed in this test. Fluid temperature fluctuations occur with rates not exceeding 10C/s and a maximum amplitude of about 200C in the downcomer and 100C on the tube sheet. Steam generator outer shell temperature varies at a rate of about +-0.80 C/min with a maximum amplitude of about 160C. These thermal transients should lead to thermally induced stresses of acceptable levels. (orig.)

Part of:
Thermal-hydraulic characteristics of pressurized water reactors during commercial operation. Pt. 2

Additional details

Additional titles

Subtitle (English)
PWR steam generator response to a scram at 50% load and an open grid transient (Bugey-4 nuclear power plant)

Publishing Information

Journal Title
Nucl. Eng. Des.
Journal Volume
70
Journal Issue
2
Series
Nucl. Eng. Des.
Journal Page Range
173-186
ISSN
0029-5493

Optional Information