3D pulmonary perfusion MRI and MR angiography of pulmonary embolism in pigs after a single injection of a blood pool MR contrast agent
Creators
- 1. Department of Radiology, Innovative Cancer Diagnostic and Therapy, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg (Germany)
- 2. Department of Medical Physics in Radiology, Innovative Cancer Diagnostic and Therapy, German Cancer Research Center (DKFZ), Im Neuenheimer Feld 280, 69120, Heidelberg (Germany)
Description
The purpose of this study was to assess the feasibility of contrast-enhanced 3D perfusion MRI and MR angiography (MRA) of pulmonary embolism (PE) in pigs using a single injection of the blood pool contrast Gadomer. PE was induced in five domestic pigs by injection of autologous blood thrombi. Contrast-enhanced first-pass 3D perfusion MRI (TE/TR/FA: 1.0 ms/2.2 ms/40 ; voxel size: 1.3 x 2.5 x 4.0 mm3; TA: 1.8 s per data set) and high-resolution 3D MRA (TE/TR/FA: 1.4 ms/3.4 ms/40 ; voxel size: 0.8 x 1.0 x 1.6 mm3) was performed during and after a single injection of 0.1 mmol/kg body weight of Gadomer. Image data were compared to pre-embolism Gd-DTPA-enhanced MRI and post-embolism thin-section multislice CT (n=2). SNR measurements were performed in the pulmonary arteries and lung. One animal died after induction of PE. In all other animals, perfusion MRI and MRA could be acquired after a single injection of Gadomer. At perfusion MRI, PE could be detected by typical wedge-shaped perfusion defects. While the visualization of central PE at MRA correlated well with the CT, peripheral PE were only visualized by CT. Gadomer achieved a higher peak SNR of the lungs compared to Gd-DTPA (21±8 vs. 13±3). Contrast-enhanced 3D perfusion MRI and MRA of PE can be combined using a single injection of the blood pool contrast agent Gadomer. (orig.)
Availability note (English)
Available from: http://dx.doi.org/10.1007/s00330-004-2282-8Additional details
Identifiers
Publishing Information
- Journal Title
- European Radiology
- Journal Volume
- 14
- Journal Issue
- 7
- Journal Page Range
- p. 1291-1296
- ISSN
- 0938-7994
- CODEN
- EURAE3
INIS
- Country of Publication
- Germany
- Country of Input or Organization
- Germany
- INIS RN
- 35072785
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ARTERIES; BIOMEDICAL RADIOGRAPHY; BLOOD; DEFECTS; DTPA; ENZYMES; IMAGES; INDUCTION; INJECTION; LUNGS; RESOLUTION; SWINE
- Descriptors DEC
- AMINO ACIDS; ANIMALS; BIOLOGICAL MATERIALS; BLOOD VESSELS; BODY; BODY FLUIDS; CARBOXYLIC ACIDS; CARDIOVASCULAR SYSTEM; CHELATING AGENTS; DIAGNOSTIC TECHNIQUES; DOMESTIC ANIMALS; DRUGS; INTAKE; MAMMALS; MATERIALS; MEDICINE; NUCLEAR MEDICINE; ORGANIC ACIDS; ORGANIC COMPOUNDS; ORGANS; PROTEINS; RADIOLOGY; RADIOPROTECTIVE SUBSTANCES; RESPIRATORY SYSTEM; RESPONSE MODIFYING FACTORS; VERTEBRATES