Published November 1997 | Version v1
Report Open

Passive heat removal in CANDU

Creators

  • 1. Sheridan Park Research Community, Atomic Energy of Canada Ltd, Mississauga, ON (Canada)

Description

CANDU has a tradition of incorporating passive systems and passive components whenever they are shown to offer performance that is equal to or better than that of active systems, and to be economic. Examples include the two independent shutdown systems that employ gravity and stored energy respectively, the dousing subsystem of the CANDU 6 containment system, and the ability of the moderator to cool the fuel in the event that all coolant is lost from the fuel channels. CANDU 9 continues this tradition, incorporating a reserve water system (RWS) that increases the inventory of water in the reactor building and profiles a passive source of makeup water and/or heat sinks to various key process systems. The key component of the CANDU 9 reserve water system is a large (2500 cubic metres) water tank located at a high elevation in the reactor building. The reserve water system, while incorporating the recovery system functions, and the non-dousing functions of the dousing tank in CANDU 6, embraces other key systems to significantly extend the passive makeup/heat sink capability. The capabilities of the reserve water system include makeup to the steam generators secondary side if all other sources of water are lost; makeup to the heat transport system in the event of a leak in excess of the D2O makeup system capability; makeup to the moderator in the event of a moderator leak when the moderator heat sink is required; makeup to the emergency core cooling (ECC) system to assure NPSH to the ECC pumps during a loss of coolant accident (LOCA), and provision of a passive heat sink for the shield cooling system. Other passive designs are now being developed by AECL. These will be incorporated in future CANDU plants when their performance has been fully proven. This paper reviews the passive heat removal systems and features of current CANDU plants and the CANDU 9, and briefly reviews some of the passive heat removal concepts now being developed. (author)

Files

29024321.pdf

Files (345.3 kB)

Name Size Download all
md5:53fb67b349275e542d5dc00844e9c4b2
345.3 kB Preview Download
Part of:
Advances in heavy water reactor technology. Proceedings of a technical committee meeting

Additional details

Publishing Information

Imprint Title
Advances in heavy water reactor technology. Proceedings of a technical committee meeting
Imprint Pagination
475 p.
Journal Page Range
p. 137-150.
ISSN
1011-4289
Report number
IAEA-TECDOC--984

Conference

Title
Technical committee meeting on advances in heavy water reactor technology.
Dates
29 Jan - 1 Feb 1996.
Place
Mumbai (India).

INIS

Country of Publication
International Atomic Energy Agency (IAEA)
Country of Input or Organization
International Atomic Energy Agency (IAEA)
INIS RN
29024321
Subject category
S21: SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS;
Resource subtype / Literary indicator
Conference
Descriptors DEI
AFTER-HEAT; AFTER-HEAT REMOVAL; CANDU TYPE REACTORS; DESIGN; ECONOMICS; INVENTORIES; NUCLEAR POWER PLANTS; SHUTDOWN; WATER
Descriptors DEC
HEAVY WATER MODERATED REACTORS; HYDROGEN COMPOUNDS; NUCLEAR FACILITIES; OXYGEN COMPOUNDS; POWER PLANTS; POWER REACTORS; PRESSURE TUBE REACTORS; REACTORS; REMOVAL; THERMAL POWER PLANTS; THERMAL REACTORS

Optional Information

Notes
9 figs.