Fitness for service after a LOCA: A process applied to Pickering NGS Unit 2

  • 1. Ontario Hydro, Pickering, Ontario (Canada). Pickering NGS
  • 2. Ontario Hydro, Toronto, Ontario (Canada). Nuclear Technology Services

Description

The fitness for service process provides a unique proven methodology for assessing and correcting post-LOCA damage, essential to plant restart. The process uses the as-built plant configuration for modelling input and features self correcting feedback from inspection to validate assessment models. This paper focuses on the process steps and the infrastructure necessary to execute the process

Additional details

Publishing Information

Publisher
American Society of Mechanical Engineers.
Imprint Place
New York, NY (United States)
ISBN
0-7918-1778-4
Imprint Title
Pressure vessels and piping design, analysis, and severe accidents. PVP-Volume 331
Imprint Pagination
219 p.
Journal Page Range
p. 129-133.

Conference

Title
American Society of Mechanical Engineers (ASME) pressure vessels and piping conference.
Dates
21-26 Jul 1996.
Place
Montreal (Canada).

Optional Information

Secondary number(s)
CONF-960706--.