Radiation protection of patients in diagnostic and interventional radiology in Asian countries: Impact of an IAEA project
Creators
- 1. International Atomic Energy Agency (IAEA), Vienna International Centre, P.O. Box 100, Vienna (Austria)
- 2. University of Belgrade, Vinca Institute of Nuclear Sciences, Radiation Protection Department, Mike Petrovica Alasa 12-14, P.O. Box 522, 11001 Belgrade (Serbia)
- 3. Hamad Medical Corp, Occupational Health and Safety, P.O. Box 1725, Doha (Qatar)
- 4. Dubai Hospital, Dubai (United Arab Emirates)
- 5. Lebanon Atomic Energy Commission (Lebanon)
- 6. National Radiation Protection Department, Iranian Nuclear Regulatory Authority, Tehran (Iran, Islamic Republic of)
- 7. Atomic Energy Commission of Syria, Damascus (Syrian Arab Republic)
- 8. Ministry of Health Malaysia, Putrajaya Wilayah Persekutuan (Malaysia)
- 9. Lady Ridgeway Hospital for Children, Dr Danister de Silva Mawatha, Colombo (Sri Lanka)
- 10. Center for Device Regulation, Radiation Health, and Research Department of Health, Manila (Philippines)
- 11. Al-Sabah Hospital (Kuwait)
- 12. Institute of Nuclear Medicine and Oncology, PAEC, Lahore (Pakistan)
Description
Recognizing the lack of information on image quality and patient doses in most countries in Asia, the International Atomic Energy Agency (IAEA) initiated a project to assess the status of imaging technology, practice in conventional radiography, mammography, computed tomography (CT) and interventional procedures, and to implement optimisation actions. A total of 20 countries participated. Obsolete practices of use of fluoroscopy for positioning, photofluorography, chest fluoroscopy and conventional tomography were reported by 4 out of 7 countries that provided this information. Low-kV technique for chest radiography is in use in participating countries for 20–85% of cases, and manual processing is in 5–85% of facilities in 5 countries. Instances of the use of adult CT protocol for children in three participating countries were observed in 10–40% of hospitals surveyed. After implementation of a Quality Control programme, the image quality in conventional radiography improved by zero to 13 percentage points in certain countries and dose reduction was from 10% to 85%. In mammography, poor quality, ranging from 10 to 29% of images in different countries was observed. The project increased attention to dose quantities and dose levels in computed tomography, although doses in most cases were not higher than reference levels. In this study 16–19% of patients in interventional cardiology received doses that have potential for either stochastic risk or tissue reaction. This multi-national study is the first of its kind in the Asia, and it provided insight into the situation and opportunities for improvement
Availability note (English)
Available from http://dx.doi.org/10.1016/j.ejrad.2012.06.019Additional details
Identifiers
- DOI
- 10.1016/j.ejrad.2012.06.019;
- PII
- S0720-048X(12)00286-0;
Publishing Information
- Journal Title
- European Journal of Radiology
- Journal Volume
- 81
- Journal Issue
- 10
- Journal Page Range
- p. e982-e989
- ISSN
- 0720-048X
- CODEN
- EJRADR
INIS
- Country of Publication
- Netherlands
- Country of Input or Organization
- Cuba
- INIS RN
- 45043905
- Subject category
- S62: RADIOLOGY AND NUCLEAR MEDICINE;
- Descriptors DEI
- ADULTS; ANIMAL TISSUES; ASIA; CHEST; CHILDREN; COMPUTERIZED TOMOGRAPHY; DOSES; FLUOROSCOPY; HAZARDS; HOSPITALS; IAEA; IMAGES; INFORMATION; MAMMARY GLANDS; PATIENTS; PROCESSING; QUALITY CONTROL; RADIATION PROTECTION; STOCHASTIC PROCESSES
- Descriptors DEC
- AGE GROUPS; ANIMALS; BIOMEDICAL RADIOGRAPHY; BODY; BUILDINGS; CONTROL; DIAGNOSTIC TECHNIQUES; GLANDS; INTERNATIONAL ORGANIZATIONS; MAMMALS; MAN; MEDICAL ESTABLISHMENTS; MEDICINE; NUCLEAR MEDICINE; ORGANS; PRIMATES; RADIOLOGY; TOMOGRAPHY; VERTEBRATES
Optional Information
- Copyright
- Copyright (c) 2012 Elsevier Science B.V., Amsterdam, The Netherlands, All rights reserved.