High resolution magnetic spectrometer for antiproton physics at rest and low energies

Description

A spectrometer is being installed in a high-intensity antiproton beam (LESBII) at the AGS. The beam momentum entering the target will be known to approximately +- 1/2%. The target is surrounded by a stereoscopic cylindrical drift chamber, and thus the total charge of the event will be measured. Since the vertex will be reconstructed with an accuracy of approximately +- 2 mm, studies of annihilations with high resolution down to approximately 150 MeV/c will be possible. On one side of the target a large-aperture (2.3 x .62 m2) magnet covered on both sides with drift chambers and triggering--TOF scintillation counters, will measure particle and γ-ray energies with high resolution, as well as identify particles. The primary objective is to look for peaks in the γ spectra coming from annihilations at rest by converting them in a thin (.05 x0) radiator before the magnet. Narrow peaks (< 1 MeV) which are produced with frequencies of approximately 10-3 or better are expected to be seen as 5 sigma effects. The principle and details of the spectrometer are presented

Availability note (English)

MF available from INIS under the Report Number; Available from NTIS., MF A01.

Files

Restricted

The record is publicly accessible, but files are restricted to users with access.

Additional details

Publishing Information

Imprint Pagination
14 p.
Report number
BNL--24662

Conference

Title
4. European anti-proton symposium.
Dates
26 - 30 Jun 1978.
Place
Strasbourg, France.

Optional Information

Secondary number(s)
CONF-7806108--1.