Published May 11, 1992 | Version v1
Journal article

Characterization by radiotracer of flow dynamics in laboratory and pilot-plant molecular sieves columns dehydrating organic liquids

  • 1. Institute of Nuclear Physics, Tirana (Albania)
  • 2. Faculty of Natural Sciences, Tirana (Albania). Dept. of Chemical Engineering
  • 3. Institute of Research and Development, Tirana (Albania)

Description

Experiments with 113mIn radiotracer in 0.01M aqueous solutions of EDTA have been carried out to investigate the fluid flow dynamics in columns of three different diameters filled with molecular sieve spherical particles. The dependence of the Peclet number upon the column diameter-to-particle diameter ratio is demonstrated and irregularities and fluctuations for ratios smaller than 10 are observed. The influence of these phenomena on the adsorption process was investigated. (author) 11 refs.; 3 figs

Additional details

Publishing Information

Journal Title
Journal of Radioanalytical and Nuclear Chemistry
Journal Volume
165
Journal Issue
1
Series
Letters.
Journal Page Range
p. 1-8.
ISSN
0236-5731
CODEN