Published March 2018 | Version v1
Journal article

Effects of Droplet Flow Rate on Boiling Curve in Spray Cooling

  • 1. Andong Nat'l Univ., Andong (Korea, Republic of)

Description

The heat flux of spray cooling in nucleate boiling and film boiling region were experimentally investigated under the experimental condition that the droplet flow rate is in the range 0.00002m3/(m2s)-0.003m3/(m2s). The following results were obtained. The heat flux of spray cooling increased with increasing droplet flow rate in both surface temperature regions of nucleate boiling and film boiling. Particularly, the heat flux of the nucleate boiling region, including CHF, increased more greatly. This experimental result indicates that for nucleate boiling, the effect of phase-change heat transfer by droplet flow rate was more remarkably apparent compared to film boiling. However, the effect of droplet temperature on the heat flux of spray cooling appeared unclear in both surface temperature regions

Additional details

Publishing Information

Journal Title
Transactions of the Korean Society of Mechanical Engineers. B
Journal Volume
42
Journal Issue
3
Series
17 refs, 14 figs
Journal Page Range
p. 161-168
ISSN
1226-4881

INIS

Country of Publication
Korea, Republic of
Country of Input or Organization
Korea, Republic of
INIS RN
49069449
Subject category
S42: ENGINEERING;
Descriptors DEI
DROPLETS; FILM BOILING; FLOW RATE; HEAT FLUX; HEAT TRANSFER; NUCLEATE BOILING; SPRAY COOLING; SURFACES
Descriptors DEC
BOILING; COOLING; ENERGY TRANSFER; PARTICLES; PHASE TRANSFORMATIONS